English term
gate
English to German
Medical
Medical: Instruments
CT Scanner
Not reviewing the center of the VOI in all gates.
Warning
Incorrect diagnosis.
Always review the center of VOI points in all gates to ensure that they have been properly placed with regards to the lesion. This ensures that the inputs to the VOI displacement calculation are correct.
thanks for help as I'm a bit confused by this term
Warning
Incorrect diagnosis.
Always review the center of VOI points in all gates to ensure that they have been properly placed with regards to the lesion. This ensures that the inputs to the VOI displacement calculation are correct.
thanks for help as I'm a bit confused by this term
Proposed translations
(German)
3 | Tor |
Johannes Gleim
![]() |
2 | Öffnung, Durchtrittsöffnung, Fenster |
Alexandra Villeminey
![]() |
Proposed translations
3 hrs
Selected
Tor
Wenn gating als Steuerung bezeichnet wird, ist "gate" folglicherweise ein Steuerelement, in der Elektronik häufig als Gate oder Tor bezeichnet.
gate [elec.] der Steueranschluss
gate [comp.] das Steuerelement
gate also [tech.] das Tor
aber auch:
to gate [tech.] anschneiden | schnitt an, angeschnitten |
to gate versperren | versperrte, versperrt |
to gate out [tech.] ausblenden | blendete aus, ausgeblendet |
http://dict.leo.org/ende?lp=ende&lang=de&searchLoc=0&cmpType...
CT Scanner - Esaote - 9800
Part details: CT console, gate control board - 46188562G1
http://www.medwow.com/ct-console-gate-control-board-46188562...
After the contrast is administered, the CT scan can be performed. What this entails is for the patient to lay on a bed which then moves through a CT scanner gate. The entire test usually only takes 3-4 mintues, depending on how much of your body is being scanned.
http://www.zocdoc.com/answers/11358/what-is-a-rectal-contras...
Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours
:
There is concern about inconsistent attenuation correction in 4D PET due to mismatches between PET and CT [23]. Even if 4D CT is used for attenuation correction of the corresponding 4D PET, errors due to the mismatch of CT and corresponding PET gates may be introduced due to differences in the binning methods used for reconstructing 4D CT and 4D PET [24].
:
The list-mode data were reconstructed using three methods: (1) standard 3D PET reconstruction, resulting in a free-breathing PET image for a 24-min acquisition; (2) phase-based 4D PET reconstruction, with eight gates; and (3) reconstruction using the OG algorithm.
:
One could prospectively gate the CT scanner to acquire attenuation data at the respiratory amplitude determined by the OG calculation, and the patient would receive very little additional radiation exposure from the prospectively gated CT scan. This was not possible in the retrospective study described here. For patients with an irregular or nonphysiological breathing pattern, choosing a different CT gate for the attenuation correction might circumvent possible errors in attenuation correction.
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3070073/
Another way is to gate the CT scanner (i.e., images are only acquired at a particular breathing phase).
http://books.google.de/books?id=nDmq_2Ww5hwC&pg=PA263-IA23&l...
4-D CT Simulator is a CT or "cat" scanner with special software. During a 4-D CT scan, data is collected in discreet packets of time that are correlated with patient motion such as breathing. This allows doctors to "gate" or plan radiation treatment around your breathing or other motions your body makes at rest. This is especially useful when treating lung cancer where doctors can time the radiation to a special point in the breathing cycle to make the treatment more accurate.
http://www.fccc.edu/patients/preparingProcedures/radiationTh...
Betrachtet man alle Referenzen zusammen, so könnte es ein "Tor" sein, das immer zu bestimmten Zeitpunkten geöffnet (angesteuert oder angeschnitten) wird.
--------------------------------------------------
Note added at 22 hrs (2012-03-13 18:27:35 GMT)
--------------------------------------------------
oder auch ein Fenster, wobei dies sowohl örtlich (bestimmter Bereich, als auch zeitlich (Impulse, auch getriggert) verstanden werden kann.
Im CT-Bild wird die Schwächung des Gewebes für das von der Röhre emittierte Röntgenspektrum in Form von Grauwerten dargestellt. Die Schwächungswerte werden in sogenannte CT-Zahlen umgerechnet und diese auf der Hounsfield-Skala ausgegeben. Luft hat definitionsgemäß die CT-Zahl -1000 und Wasser den Wert 0. Der Grund für die Umrechnung ist, dass die spektrale Zusammensetzung der Röntgenstrahlung in Abhängigkeit von Aufnahmeparametern und verwendeter Vorfilterung stark variiert. Ein CT-Bild, das Schwächungswerte direkt darstellen würde, würde jeweils unterschiedlich ausfallen. Eine Vergleichbarkeit von Bildern, wie sie für die Befundung in der Medizin unabdingbar ist, wäre so nicht möglich. Durch Normierung der gemessenen Schwächung auf die Schwächungswerte von Wasser und Luft wird dieses Problem umgangen. Für die bildliche Darstellung wird jeder CT-Zahl ein Grauwert zugeordnet. Da das menschliche Auge nicht in der Lage ist, diese 4000 Grauwerte zu differenzieren, wird die Fensterung je nach untersuchtem Organsystem anders gewählt.
http://de.wikipedia.org/wiki/Computertomographie
Die englische Seite für CT-Tomographie erwähnt kein "gate" oder "gating". Das findet sich aber auf der englischen Seite für MR-Tomographie.
Magnetic resonance gated intracranial CSF dynamics (MR-GILD)Magnetic resonance gated intracranial cerebrospinal fluid (CSF) or liquor dynamics (MR-GILD) technique is an MR sequence based on bipolar gradient pulse used to demonstrate CSF pulsatile flow in ventricles, cisterns, aqueduct of Sylvius and entire intracranial CSF pathway. It is a method for analyzing CSF circulatory system dynamics in patients with CSF obstructive lesions such as normal pressure hydrocephalus. It also allows visualization of both arterial and venous pulsatile blood flow in vessels without use of contrast agents.[30][31]
http://en.wikipedia.org/wiki/Magnetic_resonance_imaging
gate [elec.] der Steueranschluss
gate [comp.] das Steuerelement
gate also [tech.] das Tor
aber auch:
to gate [tech.] anschneiden | schnitt an, angeschnitten |
to gate versperren | versperrte, versperrt |
to gate out [tech.] ausblenden | blendete aus, ausgeblendet |
http://dict.leo.org/ende?lp=ende&lang=de&searchLoc=0&cmpType...
CT Scanner - Esaote - 9800
Part details: CT console, gate control board - 46188562G1
http://www.medwow.com/ct-console-gate-control-board-46188562...
After the contrast is administered, the CT scan can be performed. What this entails is for the patient to lay on a bed which then moves through a CT scanner gate. The entire test usually only takes 3-4 mintues, depending on how much of your body is being scanned.
http://www.zocdoc.com/answers/11358/what-is-a-rectal-contras...
Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours
:
There is concern about inconsistent attenuation correction in 4D PET due to mismatches between PET and CT [23]. Even if 4D CT is used for attenuation correction of the corresponding 4D PET, errors due to the mismatch of CT and corresponding PET gates may be introduced due to differences in the binning methods used for reconstructing 4D CT and 4D PET [24].
:
The list-mode data were reconstructed using three methods: (1) standard 3D PET reconstruction, resulting in a free-breathing PET image for a 24-min acquisition; (2) phase-based 4D PET reconstruction, with eight gates; and (3) reconstruction using the OG algorithm.
:
One could prospectively gate the CT scanner to acquire attenuation data at the respiratory amplitude determined by the OG calculation, and the patient would receive very little additional radiation exposure from the prospectively gated CT scan. This was not possible in the retrospective study described here. For patients with an irregular or nonphysiological breathing pattern, choosing a different CT gate for the attenuation correction might circumvent possible errors in attenuation correction.
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3070073/
Another way is to gate the CT scanner (i.e., images are only acquired at a particular breathing phase).
http://books.google.de/books?id=nDmq_2Ww5hwC&pg=PA263-IA23&l...
4-D CT Simulator is a CT or "cat" scanner with special software. During a 4-D CT scan, data is collected in discreet packets of time that are correlated with patient motion such as breathing. This allows doctors to "gate" or plan radiation treatment around your breathing or other motions your body makes at rest. This is especially useful when treating lung cancer where doctors can time the radiation to a special point in the breathing cycle to make the treatment more accurate.
http://www.fccc.edu/patients/preparingProcedures/radiationTh...
Betrachtet man alle Referenzen zusammen, so könnte es ein "Tor" sein, das immer zu bestimmten Zeitpunkten geöffnet (angesteuert oder angeschnitten) wird.
--------------------------------------------------
Note added at 22 hrs (2012-03-13 18:27:35 GMT)
--------------------------------------------------
oder auch ein Fenster, wobei dies sowohl örtlich (bestimmter Bereich, als auch zeitlich (Impulse, auch getriggert) verstanden werden kann.
Im CT-Bild wird die Schwächung des Gewebes für das von der Röhre emittierte Röntgenspektrum in Form von Grauwerten dargestellt. Die Schwächungswerte werden in sogenannte CT-Zahlen umgerechnet und diese auf der Hounsfield-Skala ausgegeben. Luft hat definitionsgemäß die CT-Zahl -1000 und Wasser den Wert 0. Der Grund für die Umrechnung ist, dass die spektrale Zusammensetzung der Röntgenstrahlung in Abhängigkeit von Aufnahmeparametern und verwendeter Vorfilterung stark variiert. Ein CT-Bild, das Schwächungswerte direkt darstellen würde, würde jeweils unterschiedlich ausfallen. Eine Vergleichbarkeit von Bildern, wie sie für die Befundung in der Medizin unabdingbar ist, wäre so nicht möglich. Durch Normierung der gemessenen Schwächung auf die Schwächungswerte von Wasser und Luft wird dieses Problem umgangen. Für die bildliche Darstellung wird jeder CT-Zahl ein Grauwert zugeordnet. Da das menschliche Auge nicht in der Lage ist, diese 4000 Grauwerte zu differenzieren, wird die Fensterung je nach untersuchtem Organsystem anders gewählt.
http://de.wikipedia.org/wiki/Computertomographie
Die englische Seite für CT-Tomographie erwähnt kein "gate" oder "gating". Das findet sich aber auf der englischen Seite für MR-Tomographie.
Magnetic resonance gated intracranial CSF dynamics (MR-GILD)Magnetic resonance gated intracranial cerebrospinal fluid (CSF) or liquor dynamics (MR-GILD) technique is an MR sequence based on bipolar gradient pulse used to demonstrate CSF pulsatile flow in ventricles, cisterns, aqueduct of Sylvius and entire intracranial CSF pathway. It is a method for analyzing CSF circulatory system dynamics in patients with CSF obstructive lesions such as normal pressure hydrocephalus. It also allows visualization of both arterial and venous pulsatile blood flow in vessels without use of contrast agents.[30][31]
http://en.wikipedia.org/wiki/Magnetic_resonance_imaging
4 KudoZ points awarded for this answer.
1 day 14 hrs
Öffnung, Durchtrittsöffnung, Fenster
In meinem Medizinwörterbuch von Langenscheidt steht für Gate - Öffnung, Durchtrittsöffnung, Fenster. Vielleicht kannst du damit etwas anfangen. Aber es wäre hilfreich zu wissen, wofür VOI steht, um das näher zu überprüfen.
--------------------------------------------------
Note added at 1 día14 horas (2012-03-14 10:18:53 GMT)
--------------------------------------------------
Schau mal hier auf Seite 5 unter -Da die Prognose ... (Ich denke, das spricht für Fenster)
http://www.diss.fu-berlin.de/diss/servlets/MCRFileNodeServle...
--------------------------------------------------
Note added at 1 día14 horas (2012-03-14 10:18:53 GMT)
--------------------------------------------------
Schau mal hier auf Seite 5 unter -Da die Prognose ... (Ich denke, das spricht für Fenster)
http://www.diss.fu-berlin.de/diss/servlets/MCRFileNodeServle...
Note from asker:
VOI = Volume of interest |
Discussion
Außerdem ist ein Trigger ein Auslöser, ein Gate aber lässt Dinge durch.
Trigger: Auslöser
Gate: Durchlass
Kann man also nicht gleichsetzen.
gating ist Steuerung/Triggering; ist gate demnach Trigger?