Test Run
Before starting up the machine, bar over the machine for 2~3 revolutions with hands, and the basic compressor shall rotate without obstacle. Open the intake valve and exhaust valve, when the gas intake pressure rises to the set point, jog the compressor and check whether the basic compressor and cooling water are normal.
Antes de poner en marcha la máquina,...
Antes de poner en marcha la máquina,...
Proposed translations
(Spanish)
4 +1 | virar/girar el motor... |
Ignacio González Sánchez
![]() |
4 | rotar la máquina |
Daniel Delgado
![]() |
Proposed translations
+1
1 day 2 hrs
Selected
virar/girar el motor...
Para el caso de motores lo que se utiliza es el término "virar" para ese procedimiento de "hacer que gire" de forma manual, de forma de verificar funcionamiento, previo a darle arranque. Es un procedimiento normal también en los motores de barcos, etc. También puede usarse "girar".
4 KudoZ points awarded for this answer.
Comment: "Gracias!"
1 hr
English term (edited):
bar over the machine
rotar la máquina
En https://core.ac.uk/download/pdf/147259088.pdf
en la sección "Practical Tips for Startup Operation, Field and Shop Overhaul", se indica:
"All manuals will tell the user to rotate or bar over the compressor prior to startup-especially prior to restarting a machine which has been running. Uneven cooling of the rotors and casing can cause a lockup or rub."
"After a period of trouble free service, complacency can set in and operations people will sometimes phase out the rotation process. This is often due to the extra effort required to access a satisfactory location to bar over the machine. If the process requires numerous starts and stops, a turning lug could greatly reduce the time and effort required"
Es decir, "bar over" es rotar el compresor sin utilizar el motor, manualmente. Supongo que "bar" tiene relación con "handle bar", una manija.
En el párrafo que se está traduciendo ya se aclara que la rotación es "a mano", por lo que no hacen falta más aclaraciones.
Otra referencia en igual sentido:
"Before starting the compressor, bar over the machine by hand where possible to ensure free rotation and that no metallic 'knocking' noise is evident."
https://www.scribd.com/document/325376595/High-pressure-air-...
--------------------------------------------------
Note added at 1 hr (2021-05-24 22:35:56 GMT)
--------------------------------------------------
En todos los casos citados se trata de compresores industriales muy grandes, extremadamente costosos y frecuentemente sin spare (es decir, equipo único en la planta), por lo que toman muchísimas precauciones antes y durante su (re)arranque para evitar cualquier daño al equipo.
en la sección "Practical Tips for Startup Operation, Field and Shop Overhaul", se indica:
"All manuals will tell the user to rotate or bar over the compressor prior to startup-especially prior to restarting a machine which has been running. Uneven cooling of the rotors and casing can cause a lockup or rub."
"After a period of trouble free service, complacency can set in and operations people will sometimes phase out the rotation process. This is often due to the extra effort required to access a satisfactory location to bar over the machine. If the process requires numerous starts and stops, a turning lug could greatly reduce the time and effort required"
Es decir, "bar over" es rotar el compresor sin utilizar el motor, manualmente. Supongo que "bar" tiene relación con "handle bar", una manija.
En el párrafo que se está traduciendo ya se aclara que la rotación es "a mano", por lo que no hacen falta más aclaraciones.
Otra referencia en igual sentido:
"Before starting the compressor, bar over the machine by hand where possible to ensure free rotation and that no metallic 'knocking' noise is evident."
https://www.scribd.com/document/325376595/High-pressure-air-...
--------------------------------------------------
Note added at 1 hr (2021-05-24 22:35:56 GMT)
--------------------------------------------------
En todos los casos citados se trata de compresores industriales muy grandes, extremadamente costosos y frecuentemente sin spare (es decir, equipo único en la planta), por lo que toman muchísimas precauciones antes y durante su (re)arranque para evitar cualquier daño al equipo.