Glossary entry (derived from question below)
English term or phrase:
dual energy studies
Croatian translation:
studije primjenom dvojne energije
Added to glossary by
Kristina Kolic
Dec 14, 2008 19:27
15 yrs ago
English term
Dual energy studies
English to Croatian
Tech/Engineering
Medical: Instruments
Current technologies are recommended for AEC acquisition especially on Dual Energy studies.
Proposed translations
(Croatian)
3 +3 | studije primjenom dvojne energije |
Kristina Kolic
![]() |
References
Znanstveni članak |
Ivana Zuppa-Baksa
![]() |
Change log
Jan 7, 2009 16:58: Kristina Kolic changed "Edited KOG entry" from "<a href="/profile/674600">Dinap's</a> old entry - "Dual energy studies"" to ""studije primjenom dvojne energije""
Proposed translations
+3
1 hr
Selected
studije primjenom dvojne energije
"Sustav Somatom Definition sada je instaliran širom svijeta
i pregledano je 15,000 pacijenata. Klinički potencijal sustava
dodatno je pojačan najavom 510 k odobrenja US – FDA
za six-dual energy. Ovo utire put rutinskoj primjeni tehnologije
– tvrdi kompanija Siemens. Generiranje podataka iz
izvora dvojne energije omogućavat će izravnu subtrakciju
– oduzimanje kosti u kompliciranim anatomskim regijama,
omogućit virtualnu nepojačanu jetrenu sliku, otkriti perfuzijski
defekt pluća, vizualizirati hrskavicu, ligamente i tetive,
diferencirati plak od kontrastnog sredstva."
http://www.hdimr.hr/hdimr/frame/vjesnik/RV-01-2007.pdf
i pregledano je 15,000 pacijenata. Klinički potencijal sustava
dodatno je pojačan najavom 510 k odobrenja US – FDA
za six-dual energy. Ovo utire put rutinskoj primjeni tehnologije
– tvrdi kompanija Siemens. Generiranje podataka iz
izvora dvojne energije omogućavat će izravnu subtrakciju
– oduzimanje kosti u kompliciranim anatomskim regijama,
omogućit virtualnu nepojačanu jetrenu sliku, otkriti perfuzijski
defekt pluća, vizualizirati hrskavicu, ligamente i tetive,
diferencirati plak od kontrastnog sredstva."
http://www.hdimr.hr/hdimr/frame/vjesnik/RV-01-2007.pdf
4 KudoZ points awarded for this answer.
Comment: "Hvala.Morala sam provjeriti."
Reference comments
1 hr
Reference:
Znanstveni članak
Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies
Med. Phys. Volume 13, Issue 3, pp. 334-339 (May 1986)
Issue Date: May 1986
ABSTRACT
CITING ARTICLES
Buy This PDF (US$23)
Download PDF (1332 kB) View Cart
Connotea CiteULike del.icio.us BibSonomy
Download Citation DOWNLOAD CITATION MyScitation MySCITATION
Email this abstract to a colleague EMAIL ABSTRACT Alerting options for this article ERRATUM ALERT
Research Toolkit TOOLKIT Printer Friendly View PRINT VIEW
Blog This Article BLOG THIS ARTICLE
KEYWORDS and PACS
Keywords
PHANTOMS, BIOMEDICAL RADIOGRAPHY, DIGITAL SYSTEMS, IMAGE PROCESSING, CAT SCANNING
PACS
* 87.70.Es
Biophysics, medical physics, and biomedical engineering Biomedical engineering Diagnostic methods and instrumentation
* YEAR: 1986
PUBLICATION DATA
ISSN:
0094-2405 (print)
Publisher:
AIP is a member of CrossRef AAPM
W. A. Kalender, W. H. Perman, J. R. Vetter, and E. Klotz
Siemens Medical Systems, Henkestrasse 127, 8520 Erlangen, Federal Republic of Germany
Department of Radiology, University of Wisconsin, Madison, Wisconsin 53792
We report the evaluation of a prototype dual-energy implementation using rapid kVp switching on a clinical computed tomographic scanner. The method employs prereconstruction basis material decomposition of the dual-energy projection data. Each dual-energy scan can be processed into conventional single-kVp images, basis material density images, and monoenergetic images. Phantom studies were carried out to qualitatively and quantitatively evaluate and validate the approach.
Med. Phys. Volume 13, Issue 3, pp. 334-339 (May 1986)
Issue Date: May 1986
ABSTRACT
CITING ARTICLES
Buy This PDF (US$23)
Download PDF (1332 kB) View Cart
Connotea CiteULike del.icio.us BibSonomy
Download Citation DOWNLOAD CITATION MyScitation MySCITATION
Email this abstract to a colleague EMAIL ABSTRACT Alerting options for this article ERRATUM ALERT
Research Toolkit TOOLKIT Printer Friendly View PRINT VIEW
Blog This Article BLOG THIS ARTICLE
KEYWORDS and PACS
Keywords
PHANTOMS, BIOMEDICAL RADIOGRAPHY, DIGITAL SYSTEMS, IMAGE PROCESSING, CAT SCANNING
PACS
* 87.70.Es
Biophysics, medical physics, and biomedical engineering Biomedical engineering Diagnostic methods and instrumentation
* YEAR: 1986
PUBLICATION DATA
ISSN:
0094-2405 (print)
Publisher:
AIP is a member of CrossRef AAPM
W. A. Kalender, W. H. Perman, J. R. Vetter, and E. Klotz
Siemens Medical Systems, Henkestrasse 127, 8520 Erlangen, Federal Republic of Germany
Department of Radiology, University of Wisconsin, Madison, Wisconsin 53792
We report the evaluation of a prototype dual-energy implementation using rapid kVp switching on a clinical computed tomographic scanner. The method employs prereconstruction basis material decomposition of the dual-energy projection data. Each dual-energy scan can be processed into conventional single-kVp images, basis material density images, and monoenergetic images. Phantom studies were carried out to qualitatively and quantitatively evaluate and validate the approach.